Running Projects |
| |
 |
| |
Pr..No. |
Name of project |
Location |
Client |
Year |
| 1 |
Complete design 132/13.8KV KING KHALID UNIVERSITY SUBSTATION of 132/13.8KV substation with 6x132KV bays, 3x50/60 MVA transformers, 42 bays of 13.8KV switchgear, connected protection& control systems and auxiliary systems
|
ABHA KSA |
AL-Gihaz SEC-SOA |
2010 |
2 |
Complete design 132/13.8KV (OUTDOOR) SUBSTATION "TABUK #10" of 132/13.8KV substation with 11x132KV outdoor bays, 3x50/67 MVA transformers, 31 bays of 13.8KV switchgear, connected protection& control systems and auxiliary systems (Part 1)
|
TABUK KSA |
AL-Gihaz SEC-WOA |
2011 |
3 |
Complete design 13.8/11KV (AIS) switching station "Air base switching substation" of 13.8/11 KV substation with 18x13.8KV SWGR bays, 3x10/15 MVA transformers, 18 bays of 11KV switchgear, connected protection& control systems& auxiliary systems (Part 2)
|
TABUK KSA |
AL-Gihaz SEC-WOA |
2011 |
4 |
Complete design ISKAN S/S 132/33/13.8kV (INDOOR) GIS type substation, arranged in "double bus single breaker" The new substation to be installed under this PROJECT shall be fed from existing As-Salamah S/S by 132kV double circuit (D/C) overhead transmission line (OHL), which will be under a separate CONTRACT. This project includes extension of As-Salamah S/S by two (2) 132kV GIS bays, Al-Ahad S/S by four (4) 33kN (AIS) switchgears and Abu Ariesh by four (4) 33kV GIS feeders.
|
Jizan Area KSA |
AL-Gihaz SEC-WOA |
2011 |
5 |
Complete design EWWA 110/13.8KV Construction of fully automated new 110/13.8kV GIS substation with 4 incoming 110kV feeder bays, 2x110/13.8kV, 50/67 MVA Power transformer, 2x7 MVAR 13.8kV Capacitor Banks along with associated MV switchgear and civil and architectural works including 20 outgoing 13.8kV cable feeder bays in substation.
|
MAKKAH KSA |
Al-MASHARIQ SEC-WOA |
2011 |
6 |
Complete design Buraydah Center 132/13.8 KV S/S # 8832: construction of new 132/13.8KV substation in buraydah center, one(1)No. 132KV Gas insulated switchgear (GIS) with ten (10) Nos. 132/13.8KV GIS circuit breakers and associated equipment, Three (3) Nos. 132/13.8KV 60MVA, power transformer, one (1) 13.8KV switchgear with thirty eight (38) Nos. 13.8KV switchgear circuit breaker panels, three (3) Nos. 13.8KV, 7 MVAR capacitor bank& associate equipment, cables and civil work.
|
AL-QASSIM KSA |
ABB SEC-COA |
2011 |
7 |
Complete design AL-Rayyan 132/13.8 KV S/S 8173: construction of new 132/13.8KV substation in Al-Rayyan Area, Riyadh, one (1) No. 132KV SF6 Gas insulated switchgear (GIS) with ten (10) Nos. 132 KV GIS circuit breakers and associated equipment, three (3) Nos. 132/13.8KV 60MVA, power transformer, one (1) 13.8KV switchgear with thirty eight (38) Nos. 13.8KV switchgear circuit breakers panels three (3) Nos. 13.8KV 7 MVAR capacitor bank& associated equipment, auxiliary the substation will be with substation automation system (SAS)& will be remotely controlled through SCADA system through gateway& fiber optic channels from the central regional control center (CRCC).
|
AL-Rayyan Area KSA |
ABB SEC-COA |
2011 |
8 |
Complete design Hail 132/13.8KV substation in Hail City,one(1)No.132KV SF6 Gas insulated switchgear(GIS)with ten(10)Nos.132KV GIS circuit breakers and associated equipment,three(3)Nos.132/13.8KV 60MVA, power transformers,one(1)13.8KV switchgear with thirty eight(38)Nos.13.8KV switchgear circuit breaker panels,three(3)Nos.13.8KV,7MVAR capacitor bank&associated equipment,auxiliary equipment,cables and civil works.
The substation will be with substation automation system(SAS)&will be remotely controlled regional control center(CRCC).Extend the existing 132KV S/S #9030 by installing,one(1)132KV GIS bay and associated control, protection, relaying, metering, SCADA equipment,cables etc...
|
Hail City KSA |
ABB SEC-SOA |
2011 |
9 |
Al-Jillah 132/33 KV Reinforcement of the existing 132/33KV in Al Jillah Area by replacing the existing 2x50MVA 132/33KV power transformers with 2x100MVA 132/33KV power transformers and installing new seventeen (17) Nos. 33KV switchgear circuit breakers panels including control & protection, metering, SCADA, auxiliary equipment, cables and civil works with required modification/extension.
|
AL-Jillah KSA |
ABB SEC-SOA |
2011 |
10 |
Complete design Roikbah 132/13.8KV S/Construction of new 132/13.8kv in Roikbah, (9) Nos.outdoor132kv switchgear and associated equipment 3 Nos. 132/13.8kv power transformers, one (1) 13.8kv switchgear with 38 Nos. 13.8kv switchgear panels, three Nos. 13.8kv capacitor bank and associated equipment, Auxiliary equipment cables and civil works.
|
Najran KSA
110/13.8 KV |
ABB SEC-SOA |
2011 |
11 |
Complete design Jizan Medical City 132KV/13.8KV in jizan medical city, one (1) NO. 132KV SF6 GIS with 8 Nos.132kv circuit breaker and associated equipment 3 Nos. 132/13.8kv power transformers, one (1) 13.8kv switchgear with 42 Nos. 13.8kv switchgear panels, three Nos. 13.8kv capacitor bank and associated equipment, Auxiliary equipment cables and civil works.
|
Jizan KSA |
SEC-SOA |
2011 |
12 |
Extension of Existing Jizan CPS2 132/13.8 KV S/S by installing two (2) 132kv GIS bays Extend the existing 132kv s/s and associated control, protection, relaying, metering, SCADA equipment, cables.
|
Jizan KSA |
SEC-SOA |
2011 |
13 |
Complete design Khamis South S/S construction of new 132/13.8kv in Khamis south, one (1) NO. 132KV SF6 GIS with (8) Nos.132kv circuit breaker and associated equipment 3 Nos. 132/13.8kv power transformers, one (1) 13.8kv switchgear with 38 Nos. 13.8kv switchgear panels, three Nos. 13.8kv capacitor bank and associated equipment, Auxiliary equipment cables and civil works.
|
ASIR KSA |
ABB SEC-SOA |
2011 |
14 |
................
|
...... |
....... |
2011 |
|
|
|
|
|
| |
|